Tuam Tshoj Kho Mob X-ray Tube XD3A Chaw tsim tshuaj paus thiab tsum | Sailray
Kev kho mob X-ray Tube XD3A

Kev kho mob X-ray Tube XD3A

Kev kho mob X-ray Tube XD3A

Lus piav qhia luv luv:

Hom: Chaw nres tsheb anode x-ray raj
Daim ntawv thov: Rau kev kuaj mob x-ray chav tsev
Qauv: RT13A-2.6-100 sib npaug rau XD3A-3.5/100
Integrated zoo iav raj


Product Detail

Cov nqe lus them nqi & Shipping:

Khoom cim npe

Kev piav qhia

Lub raj no, RT13A-2.6-100 yog tsim los rau kev kuaj pom dav dav x-ray chav tsev thiab muaj rau lub nominal raj voltage nrog tus kheej-rhiab Circuit Court.
RT13A-2.6-100 raj muaj ib qho kev tsom.
Kev sib xyaw ua ke zoo siab nrog cov iav tsim muaj ib qho super imposed focal chaw thiab muaj zog anode.
Lub siab anode tshav kub cia muaj peev xwm ua kom muaj ntau yam kev siv rau kev kuaj mob x-ray daim ntawv thov. Ib qho tshwj xeeb tsim anode ua rau kom muaj cua sov dissipation tus nqi uas ua rau cov neeg mob siab dua thiab cov khoom lag luam ntev dua. Ib qho kev txhaj tshuaj siab tas li thaum lub sij hawm tag nrho lub raj lub neej yog ua kom ntseeg tau los ntawm lub hom phiaj siab tungsten. Kev yooj yim ntawm kev koom ua ke rau hauv cov khoom siv tau yooj yim los ntawm kev txhawb nqa dav dav.

Daim ntawv thov

RT13A-2.6-100 yog Portable Diagnostic nyob ruaj ruaj anode X-ray raj,tsim los rau kev kuaj mob x-ray chav tsev thiab muaj rau lub nominal raj voltage nrog tus kheej-rectified Circuit Court.

Technical data

Nominal Tube Voltage 10 5kv
Nominal Inverse Voltage 115 kV ua
Nominal Focal Spot 2.6 (IEC 60336/1993)
Max Anode Thaum tshav kub kub ntsiab lus 30 000 J
Lub hom phiaj 19° Nws
Filament yam ntxwv 4.5A, 7.0 ± 0.7V
Kev lim dej tas mus li Min. 0.8mmAl / 50kv (IEC60522/1999)
Lub hom phiaj khoom Tungsten
Tube tam sim no 50mA ua

Cov duab ntxaws

RT13A-2.6-100 Nws

Cov kab kos kom ntxaws

Competitive Advantage

Elevated anode tshav kub cia muaj peev xwm thiab txias
Tsis tas li ntawd high koob tawm los
Lub neej zoo heev

Ceeb toom
Nyeem cov lus ceeb toom ua ntej siv lub raj
X-ray raj yuav emit X-ray thaum nws muaj zog nrog high voltage, tshwj xeeb kev paub
yuav tsum tau ua thiab yuav tsum tau ceev faj thaum tuav nws.
1. Tsuas yog tus kws tshaj lij uas tsim nyog nrog X-Ray tube paub yuav tsum sib sau ua ke, tswj
thiab tshem lub raj.
2. Kev saib xyuas txaus yuav tsum tau ua kom tsis txhob muaj kev cuam tshuam thiab kev co rau lub raj
vim nws yog ua los ntawm cov iav fragile.
3. Kev tiv thaiv hluav taws xob ntawm lub raj raj yuav tsum tau ua kom txaus.
4. Qhov tsawg kawg nkaus sorce-skin nrug (SSD) thiab qhov tsawg kawg nkaus pom yuav tsum phim cov
kev cai thiab ua tau raws li tus qauv.
5. Lub kaw lus yuav tsum muaj kev tiv thaiv overload tiv thaiv Circuit Court, lub raj yuav yog
puas vim tsuas yog ib qho kev ua haujlwm overload.
6. Thaum pom muaj qhov txawv txav thaum lub sijhawm ua haujlwm, tam sim ntawd hloov qhov
fais fab mov thiab hu rau tus kws ua haujlwm pabcuam.
7. Yog hais tias lub raj yog nrog cov ntaub thaiv npog, kom pov tseg cov ntaub thaiv npog yuav tsum ntsib tsoomfwv
kev cai.

  • Yav dhau los:
  • Tom ntej:

  • Yam tsawg kawg nkaus Order Quantity: 1pc

    Nqe: Kev sib tham

    Ntim Cov Lus Qhia: 100pcs ib lub thawv lossis customized raws li qhov ntau

    Lub sij hawm xa tuaj: 1 ~ 2 lub lis piam raws li qhov ntau

    Cov nqe lus them nqi: 100% T / T ua ntej lossis WESTERN UNION

    Muaj peev xwm muab khoom: 1000pcs / hli

    Sau koj cov lus ntawm no thiab xa tuaj rau peb