Cov khoom no tau raug tsim thiab tsim nyob rau hauv kev pom zoo nrog cov cai hauv qab no, cov lus qhia thiab kev tsim qauv:
◆ Council Directive 93/42/EEC ntawm 14 Lub Rau Hli 1993 txog cov khoom siv kho mob(CE kos npe).
TS EN ISO 13485: 2016 Cov cuab yeej kho mob - Kev tswj hwm zoo - Cov kev xav tau rau kev tswj hwm
lub hom phiaj..
TS EN ISO 14971: 2012 Cov cuab yeej kho mob - Kev siv kev tswj hwm kev pheej hmoo rau cov cuab yeej kho mob (ISO 14971: 2007, Kho version 2007-10-01)
◆ TS EN ISO 15223-1: 2012 Cov cuab yeej kho mob - Cov cim siv nrog cov ntawv sau cov cuab yeej kho mob, daim ntawv lo thiab cov ntaub ntawv yuav tsum tau muab rau Ntu 1: Cov kev cai dav dav
◆International Electrotechnical Commission (IEC), cov qauv hauv qab no raug txiav txim siab tshwj xeeb.
Standard Reference | Cov npe |
EN 60601-2-54: 2009 | Cov khoom siv hluav taws xob kho mob - Ntu 2-54: Cov kev cai tshwj xeeb rau kev nyab xeeb thiab kev ua haujlwm tseem ceeb ntawm cov khoom siv xoo hluav taws xob rau hluav taws xob thiab xov tooj cua |
IEC 60526: Cov | High-voltage cable plug thiab socket txuas rau cov khoom siv kho mob X-ray |
IEC 60522: 1999 (TSI) | Kev txiav txim siab mus tas li pom ntawm X-ray raj sib dhos |
IEC 60613-2010 1 | Hluav taws xob, thermal thiab loading yam ntxwv ntawm rotating anode X-ray raj rau kev kuaj mob |
IEC 60601-1: 2006 | Cov khoom siv hluav taws xob kho mob - Ntu 1: Cov kev cai dav dav rau kev nyab xeeb thiab kev ua haujlwm tseem ceeb |
IEC 60601-1-3: 2008 | Cov cuab yeej siv kho mob hluav taws xob - Ntu 1-3: Cov kev cai dav dav rau kev nyab xeeb thiab kev ua haujlwm tseem ceeb - Cov Qauv Txheej Txheem: Kev tiv thaiv hluav taws xob hauv cov khoom siv kuaj X-ray |
IEC 60601-2-28: 2010 | Cov khoom siv hluav taws xob kho mob - Ntu 2-28: Cov kev cai tshwj xeeb rau kev nyab xeeb thiab kev ua haujlwm tseem ceeb ntawm X-ray raj sib dhos rau kev kuaj mob |
IEC 60336-2005 1 | Cov khoom siv hluav taws xob kho mob-X-ray raj sib dhos rau kev kuaj mob-Cov yam ntxwv ntawm cov chaw focal |
● Lub npe yog tsim raws li hauv qab no:
MWHX 7360 | Tube | A | High voltage socket nrog 90 degree kev taw qhia |
MWTX 73-0.6/1.2-150 H | B | High voltage socket nrog 270 degree kev taw qhia |
Khoom | Specification | Txuj | |
Nominal input zog (s) ntawm lub anode | F 1 | F 2 | TS EN 60613 |
20kW (50/60Hz) 30 kW (150/180 Hz | 50kW (50/60Hz) 74kW (150/180Hz) | ||
Anode tshav kub cia muaj peev xwm | 212 kJ (300 kHU) | TS EN 60613 | |
Qhov siab tshaj plaws txias peev xwm ntawm lub anode | 750w ua | ||
Thaum tshav kub kub cia muaj peev xwm | 9 00kj | ||
Max. nruam kub dissipation yam tsis muaj cua-cim | 180 W | ||
Cov khoom siv anodeAnode sab saum toj txheej khoom | Rhenium-Tungsten-TZM (RTM) Rhenium-Tungsten-(RT) | ||
Lub hom phiaj (Ref: reference axis) | 12 ° | IEC 60788 (ib.) | |
X-ray tube los ua ke inherent filtration | 1.5 hli Al / 75kV | IEC 60601-1-3: Kev qhia tshwj xeeb | |
Focal Spot nominal tus nqi | F1 (me me tsom) | F2 (loj tsom xam) | IEC 60336 (TSI) |
0.6 | 1.2 | ||
X-ray tube nominal voltageRadiographicFluoroscopic | 150kV ua 125 kV ua | TS EN 60613 | |
Cov ntaub ntawv ntawm cathode cua sov Max. tam sim no Max voltage | ≈ / AC, <20 kHz | ||
F1 | F 2 | ||
5.4 A ≈9V | 5.4 A ≈17V | ||
Cov hluav taws xob tawg ntawm 150 kV / 3mA hauv 1m nrug | ≤1.0mGy/h | IEC 60601-1-3 | |
Qhov siab tshaj plaws hluav taws xob |
430 × 430mm ntawm SID 1m | ||
X-ray raj sib dhos hnyav | Kwv yees li. 18 kg |
txwv | Kev txwv kev ua haujlwm | Kev thauj mus los thiab kev txwv cia |
Ambient kub | Los ntawm 10℃rau 40℃ | Los ntawm - 20℃to 70℃ |
txheeb ze humidity | ≤ 75% | ≤ 93% |
Barometric siab | Los ntawm 70kPa mus rau 106kPa | Los ntawm 70kPa mus rau 106kPa |
1-theem stator
Test point | C-M | C-A |
Winding kuj | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
Max.permissible khiav hauj lwm voltage (run-up) | 230V ± 10% Tawm tswv yim | |
Pom zoo ua haujlwm voltage (run-up) | 160V ± 10% Tawm tswv yim | |
Braking voltage | 70vdc ua | |
Khiav-on voltage nyob rau hauv raug | 80 vwm | |
Kev khiav hauj lwm voltage hauv fluoroscopy | 20V-40Vrms | |
Lub sijhawm ua haujlwm (nyob ntawm qhov pib qhov system) | 1.2s ib |
Ceeb toom rau interface nrog X-ray Generator
1. Vaj tse Repture
Tsis txhob tso tawm ntau tshaj lub zog rau X-ray raj sib dhos
Yog hais tias lub hwj chim input tshaj lub raj specification, nws ua rau lub overheating ntawm anode, ntxig raj iav shatter thiab thaum kawg cov nram qab no teeb meem loj vim generating over-pressure los ntawm roj vaporization nyob rau hauv lub tsev los ua ke.
Nyob rau hauv qhov xwm txheej tseem ceeb ua rau lub tsev tawg los ntawm kev thauj khoom ntau dhau, kev nyab xeeb thermal hloov tsis tuaj yeem tiv thaiv X-ray raj txawm tias nws ua haujlwm.
*Lub tsev sealing qhov chaw rupture.
*Tib neeg raug mob nrog rau kub hnyiab vim yog roj kub khiav.
*Hluav taws kub sib tsoo vim yog lub hom phiaj flaming anode.
Lub tshuab hluav taws xob xoo hluav taws xob yuav tsum muaj kev tiv thaiv kev ua haujlwm uas tswj xyuas lub zog hluav taws xob kom nyob hauv cov raj tshwj xeeb.
2. Hluav taws xob poob siab
Txhawm rau kom tsis txhob muaj kev pheej hmoo ntawm hluav taws xob poob siab, cov cuab yeej no yuav tsum tsuas yog txuas nrog cov khoom siv tiv thaiv lub ntiaj teb.
3.Tsis muaj kev hloov kho ntawm cov cuab yeej no raug tso cai!!
Ceev faj rau kev sib txuas nrog X-ray Generator
1. Tshaj qhov ntsuas
X-ray raj sib dhos tuaj yeem tawg nrog kev siv ib qho kev txhaj tshuaj ntau dua.
Thov nyeem cov ntawv qhia hnub ua kom zoo thiab ua raws li cov lus qhia.
2.Kev lim dej tas mus li
Tnws tag nrho cov pom thiab qhov kev ncua deb ntawm X-ray focal chaw thiab tib neeg lub cev yog tswj raws li txoj cai.
Thav yuav tsum ua raws li txoj cai.
3.Kev Nyab Xeeb Thermal Hloov
X-ray tube sib dhos muaj kev nyab xeeb thermal hloov los txwv tsis pub muaj zog ntxiv thaum lub raj vaj tse mus txog qhov kub thiab txias(80℃)ntawm switch-open.
Qhov hloov tsis pom zoo txuas stator coil hauv series Circuit Court.
Txawm hais tias qhov hloov pauv ua haujlwm, tsis txhob tig lub zog hluav taws xob tawm. Lub tshuab cua txias yuav tsum tau qhib yog tias siv nrog lub kaw lus.
4.Kev ua haujlwm tsis zoo
X-ray tube sib dhos tej zaum yuav muaj kev pheej hmoo ua rau poob qis vim kev ua haujlwm tsis tiav lossis tsis ua haujlwm.Yog tias muaj teeb meem loj los ntawm qhov kev pheej hmoo saum toj no, koj yuav tsum tau thov kom muaj txoj kev npaj xwm txheej ceev kom tsis txhob muaj xwm txheej zoo li no.
5. Daim ntawv thov tshiab
Yog tias koj siv cov khoom lag luam nrog daim ntawv thov tshiab tsis tau hais hauv qhov tshwj xeeb no lossis nrog ntau hom X-ray generator, thov hu rau peb kom paub meej tias nws muaj.
1 .X-ray Radiationkev tiv thaiv
Cov khoom no ua tiav cov kev cai ntawm IEC 60601-1-3.
X-ray raj sib dhos no tso tawm cov hluav taws xob xoo hluav taws xob hauv kev ua haujlwm.Tsuas yog cov neeg ua haujlwm tsim nyog thiab cov neeg ua haujlwm tau txais kev tso cai ua haujlwm X-ray raj sib dhos.
Cov teebmeem physiologic cuam tshuam yuav ua rau muaj kev phom sij rau tus neeg mob, kev tsim khoom yuav tsum tau txais kev tiv thaiv kom tsis txhob muaj hluav taws xob ionization.
2. Dielectric 0 il
X-ray raj sib dhos muaj dielectric 0il muaj rau kev ruaj ntseg siab. Raws li nws yog tshuaj lom rau tib neeg noj qab haus huv,yog tias nws raug rau thaj tsam tsis txwv,nws yuav tsum muab pov tseg raws li kev cai hauv zos.
3 .Operation Atmosphere
X-ray raj sib dhos tsis raug tso cai siv nyob rau hauv cov huab cua ntawm cov nplaim taws lossis cov roj corrosive ·
4.Kho lub raj tam sim no
Nyob ntawm cov xwm txheej ua haujlwm,cov yam ntxwv filament yuav raug hloov.
Qhov kev hloov pauv no tuaj yeem ua rau muaj kev cuam tshuam ntau dua rau X-ray raj sib dhos.
Txhawm rau tiv thaiv X-ray tube los ua kom puas,kho lub raj tam sim no tsis tu ncua.
Dhau li ntawm thaum X-ray raj muaj teeb meem arcing hauv iblsiv sijhawm ntev,yuav tsum tau kho lub raj tam sim no.
5.X-ray Tube Vaj Tse Kub
Tsis txhob kov ntawm X-ray raj lub tsev nyob saum npoo tsuas yog tom qab ua haujlwm vim qhov kub thiab txias.
Nyob twj ywm X-ray raj kom txias.
6.Txoj kev txwv
Ua ntej siv,thov paub meej tias qhov xwm txheej ib puag ncig yog nyob rau hauv kev khiav hauj lwm Iimits.
7.Txhua yam ua haujlwm tsis zoo
P1ease hu rau SAIRRAY tam sim ntawd,Yog tias pom muaj kev ua haujlwm tsis zoo ntawm X-ray raj sib dhos.
8. Pov tseg
X-ray raj sib dhos nrog rau lub raj muaj cov ntaub ntawv xws li roj thiab cov hlau hnyav uas ib puag ncig tus phooj ywg thiab pov tseg kom raug raws li kev cai lij choj hauv tebchaws yuav tsum tau lees paub.Kev pov tseg raws li kev lag luam hauv tsev lossis kev lag luam yog txwv tsis pub.Cov chaw tsim khoom muaj qhov kev paub txog kev xav tau thiab yuav siv lub X-ray raj sib dhos rov qab rau kev pov tseg.
Thov hu rau tus neeg muab kev pabcuam rau lub hom phiaj no.
Yog (A) Me Me Focal Spot
Yog (A) Loj Focal Spot
Tsev Thermal Yam ntxwv
SWB 7360A
Lim los ua ke thiab hla ntu ntawm chaw nres nkoj
Rotor Connector Wiring
Yam tsawg kawg nkaus Order Quantity: 1pc
Nqe: Kev sib tham
Ntim Cov Lus Qhia: 100pcs ib lub thawv lossis customized raws li qhov ntau
Lub sij hawm xa tuaj: 1 ~ 2 lub lis piam raws li qhov ntau
Cov nqe lus them nqi: 100% T / T ua ntej lossis WESTERN UNION
Muaj peev xwm muab khoom: 1000pcs / hli